Furnace & heating
AC repair
Heat pumps
Ductless mini splits
Carrier
Trane
GoodmanSeasonal tune-up and full diagnostic on your Carrier, Trane, or Goodman system - readings shown to you before any repair is proposed
Diagnosis first, numbers second - you approve the repair price before a single part goes in.
Get your free estimateRheem Heat Pump Service: The Orlando Owner’s Guide
Rheem heat pump service in Orlando typically runs $150 to $650 for most repairs, with the work usually completed same-day when the failing part is on our truck. If your Rheem heat pump is blowing warm air, short-cycling, or making a grinding sound near the compressor, you’re likely looking at a failed capacitor, contactor, defrost control board, or reversing valve. Luis Serrano and our crew stock genuine Rheem parts and quality aftermarket equivalents sized specifically for Orlando’s humidity load, so we can diagnose, match, and install quickly without making your family wait through another 90-degree afternoon.
Rheem heat pumps face a particular challenge in Central Florida: they run nearly year-round. While a heat pump in Ohio might log 1,200 hours annually, an Orlando unit often runs 3,000 to 4,000 hours. That’s why parts that last a decade elsewhere can fail in five to seven years here. Humidity accelerates corrosion on electrical contacts, and sustained runtime degrades capacitors faster than manufacturers’ coastal climate ratings suggest. When we open a Rheem unit in College Park or Winter Park, we usually find the failure pattern before the homeowner even describes the symptom.
Key Takeaways:
- Most Rheem heat pump repairs in Orlando land between $150 and $650, parts and labor included
- We stock Rheem-specific capacitors, contactors, defrost boards, and fan motors on our trucks for same-day service
- Every repair gets a written price before work starts, plus our 365-Day Done Right Promise
Which Rheem Models This Applies To
We service the full Rheem heat pump lineup, from the Prestige series (RP20, RP17) down through the Classic series (RP14, RP15) and the builder-grade Value series. The single biggest gotcha we see in Orlando: Rheem uses different capacitor microfarad ratings across these lines, and installing a generic 35/5 or 40/5 cap on a Prestige unit that calls for a 45/7.5 will run the compressor too hot and shorten its life. The part number is printed on the old component, and we verify it against the unit’s data plate before anything goes in.
When it comes to OEM versus aftermarket, our position is honest: for defrost control boards and reversing valves, we fit genuine Rheem parts, because the tolerances and wiring pinouts matter. For capacitors, contactors, and fan motors, quality aftermarket equivalents from suppliers like Mars, Supco, and Genteq often outperform OEM on lifespan in Orlando’s humidity, because they’re built for continuous-duty cycling. We’ll tell you which route makes sense for your specific unit and your budget, and the written price covers whichever part we agree on. No surprises, no bait-and-switch.
Styles & brands we work with







Signs Your Rheem Heat Pump Service Is Failing
- Unit hums but won’t start: Classic failed capacitor. The compressor tries to draw power, but the capacitor can’t supply the starting torque. This is the single most common Rheem heat pump repair we make in Orlando.
- Outside unit runs, but air from vents feels warm: The reversing valve may be stuck or the compressor contactor is dropping out intermittently. In cooling mode, a heat pump that’s blowing 80-degree air has either lost charge or isn’t compressing properly.
- System short-cycles every few minutes: The defrost control board may be misreading coil temperature, or a contactor is chattering. Short-cycling kills compressors fast, and we see it most often in units near the Orange County Convention Center where run hours climb high.
- Frost or ice on the outside coil when it’s 70 degrees out: Defrost board failure or a failed outdoor fan motor. The unit can’t shed heat from the coil, so it freezes. Letting this run will trip the high-pressure limit and possibly crack the coil.
- Grinding, screeching, or rattling near the outdoor unit: Failed fan motor bearings or a compressor mount that’s worked loose. The sound usually starts intermittent, then becomes constant within a week. Shut it off and call us before the motor seizes and takes the blade with it.
See the difference
Before
After
Before
After
Before
AfterReplacement Cost & What’s Included
In Orlando, expect to pay:
- Capacitor replacement: $150 to $280 installed, depending on whether it’s a single or dual run cap
- Contactor replacement: $150 to $300 installed
- Defrost control board: $250 to $500 installed, genuine Rheem board
- Outdoor fan motor: $350 to $600 installed, motor and blade health checked
- Reversing valve: $500 to $650 installed, includes refrigerant recovery and recharge
Every price is written on paper before we touch a single wire. That number includes the part, the labor, the refrigerant if needed, and the clean-up: shoe covers and drop cloths on every visit, plus a photo of the finished area before we leave. The 365-Day Done Right Promise backs every repair. If it’s not done right, we make it right, no runarounds and no fine print.
DIY or Call Us?
Here’s the honest split. What you can safely check: the thermostat settings, the breaker position, the air filter condition, and whether the outdoor unit’s clear of leaves and debris. If the unit hums and won’t start, that’s a capacitor, and a capacitor stores enough voltage to stop your heart even with the power off. If the coil is iced over, that’s a defrost board or fan motor, and opening the panel puts you near exposed 240-volt terminals. Rheem units have live capacitor terminals even when the breaker is off until the stored charge bleeds down. We don’t want a $40 part to cost you a hospital visit.
If you hear the hum, the grind, or the rattle, call (850) 845-8659. We’ll have a live person answer, get a truck out same-day in most of Orlando, and hand you a written price before anything comes apart. Tell me what you’re hearing, and I’ll tell you what it’s going to cost, before we start.
FAQs
Capacitors and contactors last 5 to 7 years in Orlando’s heat, defrost boards 8 to 10, and reversing valves often 12 to 15. But Orlando’s year-round runtime compresses those numbers. If your Rheem is 7 years old and you haven’t had a capacitor replaced yet, you’re on borrowed time, and a tune-up can pre-empt the failure. Call (850) 845-8659 and we’ll schedule a look.
For capacitors, contactors, and defrost boards, replacement is the repair. These components fail by wearing out; there’s no safe method to rebuild a capacitor or resolder a defrost board reliably in the field. For fan motors, we can occasionally save the motor with a new run capacitor or bearing service, but when the bearings are gone, the motor’s done. A fixed written price means you know before we touch anything.
Most capacitor, contactor, and defrost board swaps are done in 45 to 90 minutes. A fan motor runs 90 minutes to 2 hours. A reversing valve replacement is the longest of the common repairs, typically 3 to 4 hours because we recover refrigerant, braze in the new valve, pull a vacuum, and recharge the system. We respect your family’s time, and we work around nap schedules when it matters.
Yes. Our Orlando trucks carry the most common Rheem-specific capacitors, contactors, defrost boards, and fan motors for the Prestige, Classic, and Value series. For less common parts, we source through Rheem-authorized supply houses in the Orlando area. We are an independent service provider, not affiliated with Rheem. We stock parts for Rheem, Carrier, Trane, and Lennox to keep same-day service realistic. Call (850) 845-8659 for an exact quote, estimates are free.
Written by Luis Serrano, Owner, Meadowsweet Heating and Air Orlando at Meadowsweet Heating and Air Orlando, serving Orlando and nearby areas.